GAP-351R – G6 Series – 3U Rugged Workstation
Features
3U Rugged Workstation
510mm depth
Single Intel® Xeon® E3-1200 v5/v6 series
Single Intel® 6th/7th Gen. Core™ i7/i5/i3 series
Rear I/O connectors
Rear Power Input
Up to 15 x removable 2.5” SSD + 3 x internal 2.5” SSD
Up to 5 PCIe boards
Redundant AC or DC Power Supply
Optional Conformal Coating
MIL-STD-810G
Optional MIL-STD-461
Technical Specifications
Processor | Intel® Xeon® E3-1200 v5/v6, Intel® 6a/7a Gen. Core™ i7/i5/i3, Intel® Celeron® and Intel® Pentium® |
Memory | Up to 64GB ECC/non-ECC UDIMM, DDR4-2400MHz |
Chipset | Intel® C236 |
Network | 1 x GbE LAN with Intel® i210-AT 1 x GbE LAN with Intel® I219lm |
Storage | 6 SATA3 (6Gbps) ports; RAID 0, 1, 5, 10 |
TPM | 1 TPM Header |
Motherboard I/O | Available on the rear: 1 x VGA, 2 x USB 2.0, 2 x USB 3.0, 2 x LAN, 1 x HDMI, 1 x DVI, Audio |
Expansion slots | 3 PCI-E 3.0 x16 (run at 16/NA/16 or 16/8/8), 1 PCI-E 3.0 x1 (in x4) 1 5V PCI 32-bit slot Interface M.2: 1 PCI-E 3.0 x4 Form Factor: 2242/2260/2280 – Key: M-Key |
Operative Systems | Windows® 7, Windows® 8.1, Windows® 10 IoT Enterprise 2016, Windows® Server 2008 R2, Windows® Server 2012 R2, Windows® Server 2016, Linux |
IPMI | IPMI2.0, SPM, Watchdog; SNMP and e-mail alarms and notifications |
Monitoring | Monitoring, control, and management functions (fan speed, temperature, voltage, redundant power failure, power consumption, disk health, raid health, and memory health) |
Power Supply | 100/240 Redundant VAC 18-36 Single or Redundant VDC 36-72 Single or Redundant VDC |
Dimensions | 483 x 133 x 510 mm |
Construction | Aluminum with surface passivation treatment |
Colour | Silver |
Mounting | 3U 19” rackmount chassis Telescopic slides optional |
Configuration | Rear I/O and Power Supply |
Front Panel | Led: Led Power ON and HDD/SSD functionality; Switch: Power ON / OFF and System Reset; Connectors: 2x USB 2.0 |
Drive Bay | 1 x slim 5.25”; 5 x 3.5” bay + 1 x internal bay x 3 ODD 2.5” |
Operative Temperature | Standard: 0°C / +50°C Extended: -20°C / +60°C (depending on the configurations) |
Operative Humidity | 8% to 95% non-condensed (depending on the configurations) |
Storage Temperature | -40°C / +70°C |
Vibrations | MIL-STD-810G, Method 514.7, Cat 4 – Proc. I – 2.24 Grms, 5-500 Hz 60 min/axis for 3 axes |
Operative Shock | MIL-STD-810G Proc. I Method 516.7 – 15g / 11ms – half sine |
Transport shock | MIL-STD-810G Proc. II Method 516.7 – 30g / 9ms sawtooth |
Certifications | Directive 2014/35/UE-LVD / Directive 2014/30/UE-EMC Directive 2011/65/UE – RoHS / Regulation (EC) No 1907/2006 – REACH |