IES-3080Managed Fast/GbE switch with 2 SC fiber ports
IES-3080 is a managed Ethernet switch on DIN-rail for industrial networks, with 10/100 and 10/100/1000 copper ports and two SC fiber ports (1000Base-SX/LX, multimode or single-mode) for backbone or long-distance links.
The redundant 12~48 V power input, with overload/overcurrent and reverse-polarity protection, supports use in environments with a -40~75 °C operating range. EMC compliance covers the IEC 61000-4 immunity tests (ESD, RS, EFT, Surge) as well as CISPR 32/EN 55032 emissions.
At a glance
- Fiber ports (SFP/FX): 2
- Fiber mode: Multi-mode
- Serial interfaces: RS-232 in RJ45 connector with console cable. 9600bps, 8, N, 1
- Management: Managed
- Copper port speed: 10/100 Fast
Technical specifications
| Copper ports (RJ45/M12) | 8(10/100 Fast)2(10/100/1000 Gigabit) |
|---|---|
| Fiber ports (SFP/FX) | 2 |
| Fiber mode | Multi-modeSingle-mode |
| Serial interfaces | RS-232 in RJ45 connector with console cable. 9600bps, 8, N, 1 |
| Fiber standard | 1000Base-LX1000Base-SX |
| Fiber connector | SC |
| Optical power TX/RX | -9.5 dBm(min) |
| Management | Managed |
|---|---|
| Copper port speed | 10/100 Fast10/100/1000 Gigabit |
| Redundancy protocols | MSTPMRPO-ChainO-RingRSTP |
| Ethernet standards | IEEE 802.3, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3u, IEEE 802.3x, IEEE 802.3z |
| Forwarding mode | Store-and-forward |
| MAC table | 8192 address |
| Packet buffer | 1 Mbit |
| Priority queues | 4 queue |
| IGMP multicast groups | 1024 group |
| Power input | 12–48 V |
|---|---|
| Redundant input | Yes |
| Power consumption | 5 W |
| Alarm relay | Yes(1A@24VDC) |
| Mounting | DIN Rail Mount |
|---|---|
| Dimensions | 54.2 × 145.4 × 107.1 mm |
| Weight | 0.71 kg |
| Operating temperature | -40–75 °C-40–70 °C |
|---|---|
| IP rating | IP30 |
| Storage temperature | -40–85 °C |
| MTBF | 841599 h |
| Manufacturer warranty | 5 year |
| EMC (emission/immunity) | IEC 61000-4-5 SurgeIEC 61000-4-6 CSIEC 61000-4-8 PFMFEN 55035FCC Part 15BEN 55032CISPR 32IEC 61000-4-2 ESDIEC 61000-4-3 RSIEC 61000-4-4 EFT |
|---|---|
| Electrical safety | EN 60950-1EN 62368-1 |
| End of life (EOL) | 30/09/2026 |
|---|
Data extracted from the manufacturers' technical sheets: the official product spec sheet remains the reference for final confirmation.
Documentation
In the same family
More products from the same series: select up to 3 and compare them side by side.
In the same category

Let's talk about your project
Phone and email go straight to our technical sales team in Turin: the first answer is already a technical one.