AP418AcroPack mezzanine module for analog and digital I/O, 16 high-voltage channels
- Configurations
- 1 available configurations
AP418 brings the Industry Pack format to PCIe and retains the same functionality and the same memory map as existing Industry Pack modules, so moving to AcroPack does not change the register map. It measures 70 x 30 mm and plugs into the carrier through a downward-facing 100-pin Samtec connector, with 50 signals routed to the field. It is a COTS module for military, defense, automation, aerospace, scientific research and development laboratories.
Each channel works as an input or as an output, with the two circuits connected in tandem: loopback gives you self-test and diagnostics of open switches or short circuits, not just control. Change-of-state or level interrupts are software-programmable on each channel.
Available in the AP418E-LF configuration, with optional APSW-API software packages for Windows, Linux and VxWorks.
At a glance
- Low-side or high-side switch outputs
- Up to 2A DC per output
- No current derating at high temperature
- TTL threshold with hysteresis on inputs
- Fail-safe outputs, off at power-up
Technical specifications
| Connectors | A down facing 100 pin Samtec connector will mate with the carrier cardFifty of these signals are available as field I/O signals. |
|---|
| Channels | 16 |
|---|---|
| Digital I/O | 0 to 60V DC · 60V DC low-side or high-side switch outputs · up to 16High impedance inputs prevent loading of the input source and minimize currentIndividual outputs sink up to 2A DC continuous. No deration of output current required at elevated temperatures. |
| Isolation & signal | TTL-compatible input threshold with hysteresis |
| Board function | Analog and digital I/O |
|---|---|
| Bus interface | PCI Express Generation 1 interface |
| Dimensions | 70 x 30 mm |
|---|
| Operating temperature | −40~70 |
|---|---|
| Storage temperature | -40–125 °C |
| Certifications | RoHS |
|---|
| Operating systems | Linux(optional)VxWorks(optional)Windows(optional) |
|---|
Data extracted from the manufacturers' technical sheets: the official product spec sheet remains the reference for final confirmation.
Family configurations
The order codes of this family: the sheet applies to all of them, the detail of each configuration is in the datasheet.
| Configuration (PN) |
|---|
| AP418E-LF |
Documentation
In the same category

Let's talk about your project
Phone and email go straight to our technical sales team in Turin: the first answer is already a technical one.