IES-3240Managed Fast Ethernet switch with 24+8 ports for rugged industrial networks
IES-3240 is a managed Fast Ethernet switch with 32 10/100 RJ45 ports, intended for automation networks and industrial infrastructure that require redundancy and environmental resistance. Managed operation enables segmentation, traffic prioritization and remote configuration.
The dual 12~48 V power input with overcurrent and reverse-polarity protection sustains service continuity. The operating temperature range extending to -40~75 °C and the MTBF of 731289 h define its use in demanding environments.
At a glance
- Serial interfaces: RS-232 in RJ45 connector with console cable. 9600bps, 8, N, 1
- Management: Managed
- Copper port speed: 10/100 Fast
- Redundancy protocols: MSTP
- Switching bandwidth: 4.8 Gbps
Technical specifications
| Copper ports (RJ45/M12) | 824 |
|---|---|
| Connectors | RJ45 |
| Serial interfaces | RS-232 in RJ45 connector with console cable. 9600bps, 8, N, 1 |
| Management | Managed |
|---|---|
| Copper port speed | 10/100 Fast |
| Redundancy protocols | MSTPO-RingO-ChainRSTPMRP |
| Ethernet standards | IEEE 802.3, IEEE 802.3ad, IEEE 802.3u, IEEE 802.3x |
| Forwarding mode | Store-and-forward |
| Switching bandwidth | 4.8 Gbps |
| Switching latency | 2.96 us |
| Throughput | 3.571 Mpps |
| MAC table | 8192 address |
| Packet buffer | 1 Mbit |
| Priority queues | 4 queue |
| IGMP multicast groups | 1024 group |
| Power input | 12–48 V |
|---|---|
| Redundant input | Yes |
| Power consumption | 15 W |
| Alarm relay | Yes(1A@24VDC) |
| Mounting | DIN Rail Mount |
|---|---|
| Dimensions | 96.4 × 154 × 108.5 mm |
| Weight | 1.052 kg |
| Operating temperature | -40–75 °C-40–70 °C |
|---|---|
| IP rating | IP30 |
| Storage temperature | -40–85 °C |
| Operating altitude | 2000 m |
| MTBF | 731289 h |
| Manufacturer warranty | 5 year |
| EMC (emission/immunity) | IEC 61000-4-5 SurgeIEC 61000-4-6 CSIEC 61000-4-8 PFMFIEC 61000-4-3 RSIEC 61000-4-4 EFTEN 55032CISPR 32IEC 61000-4-2 ESDEN 55035EN 55024FCC Part 15B |
|---|---|
| Electrical safety | EN 62368-1EN 60950-1 |
| End of life (EOL) | 30/09/2026 |
|---|
Data extracted from the manufacturers' technical sheets: the official product spec sheet remains the reference for final confirmation.
Documentation
In the same family
More products from the same series: select up to 3 and compare them side by side.
In the same category

Let's talk about your project
Phone and email go straight to our technical sales team in Turin: the first answer is already a technical one.