VT8521U MicroTCA chassis with a declared operating altitude
VT852 explicitly declares the maximum operating altitude, a condition to verify when the system is meant for installations in the mountains or on board vehicles, because as pressure drops the effectiveness of air cooling changes.
The integrated power supply declares a power between 300 and 398 W. The operating temperature range runs from 0 to 55 °C and storage from -40 to 70 °C; the declared certifications are CE, FCC and UL and the front indicators also report the state of the PCI Express lanes.
At a glance
- Architecture standard: AMC
- PSU power: 300–398 W
- Operating temperature: 0–55 °C
Technical specifications
| Architecture standard | AMCAMC.1AMC.2AMC.4 |
|---|---|
| Bus interface | 100 MHz HCSL per AMC.1PCIe x1, x2, x4 or x8 lanes on each AMC slotEach AMC slot has two x4 (ports 4-7 and 8-11) |
| IPMI management | 2.0 |
| PSU power | 300–398 W |
|---|
| Rack units | 1 U |
|---|
| Storage temperature | -40–70 °C |
|---|---|
| Operating altitude | 3048 m |
| Operating temperature | 0–55 °C |
| Certifications | ULFCCCE |
|---|
Data extracted from the manufacturers' technical sheets: the official product spec sheet remains the reference for final confirmation.