VT8471U MicroTCA chassis with AC or DC power input
VT847 leaves the choice of the power input open: the same mechanical enclosure takes AC or DC modules, a condition that allows it to be used both in an equipment room and in plants fed by a backup battery.
The power supplies declare a power between 796 and 850 W, so the system covers fully populated chassis. The operating temperature range runs from 0 to 55 °C and storage from -40 to 90 °C; the declared certifications are CE, FCC and UL.
At a glance
- Architecture standard: AMC.2
- PSU power: 796–850 W
- Operating temperature: 0–55 °C
Technical specifications
| Ethernet ports | Two GbE SerDes per AMC |
|---|---|
| Connectors | SFPSMA(front) |
| Architecture standard | AMC.2 |
|---|---|
| Bus interface | 30.72MHz (Frequencies from 8MHz to 52MHz are available, default is 30.72MHz) |
| AMC slot configuration | ten mid-height AMC slots that supports 10GbE on ports 4-7 and 8-11, AMC.2 (ports 0 and 1) and AMC.3 (ports 2 and 3 are routed to adjacent slots) |
| IPMI management | 2.0 |
| PSU power | 796–850 W |
|---|
| Rack units | 1 U |
|---|
| Storage temperature | -40–90 °C |
|---|---|
| Operating temperature | 0–55 °C |
| Certifications | ULFCCCE |
|---|
Data extracted from the manufacturers' technical sheets: the official product spec sheet remains the reference for final confirmation.
Documentation
In the same category

Let's talk about your project
Phone and email go straight to our technical sales team in Turin: the first answer is already a technical one.