cPS-P325/AC cPS-H325-HH cPS-P325/48 cPS-H325/24 cPS-H325/110 cPS-H325/WDC cPS-H640/AC cPS-H640/48
cPS-P325/AC
cPS-H325-HH
cPS-P325/48 cPS-H325/24 cPS-H325/110 cPS-H325/WDC cPS-H640/AC cPS-H640/48
PICMG®
Standards
PICMG 2.11 CompactPCI PICMG 2.11 CompactPCI 47-pin
Form Factor 3U cPCI
2-slot
3U cPCI
2-slot
3U cPCI
2-slot
3U cPCI
2-slot
3U cPCI
2-slot
6U cPCI
2-slot
6U cPCI
2-slot
Input

Voltage

90÷264 VAC 36÷75 VDC 18÷36 VDC 66÷160 VDC 16÷160 VDC 100÷240 10% V AC 36÷72 V DC
Input
Frequency
47÷63 Hz DC DC DC DC 50-60 5% Hz DC
Input
Current
3.6A @ 230 VAC 6.3A @ 48 VDC 14A @ 24 VDC 2.8A @ 110 VDC 1.3A @ 110VDC
3.3A @ 110VDC
0.45A @ 110VDC
5.1A @115 V AC / 2.5A @
230 V AC
12A @ 48 V DC
Inrush
Current
15A @ 240 VAC 12A @ 75 VDC 10.5A @ 110 VDC 27A @ 110 VDC < 30 A @230 V AC N/A
Output
Current / Voltage
25A @ 5V
20A @ 3.3V
4A @ 12V
1A @ -12V
25A @ 5V
20A @ 3.3V
4A @ 12V
1A @ -12V
25A @ 5V
18A @ 3.3V
5A @ 12V
0.5A @ -12V
25A @ 5V
18A @ 3.3V
5A @ 12V
0.5A @ -12V
20A @ 5V
20A @ 3.3V
11A @ 12V
1A @ -12V
40A @ 5V
50A @ 3.3V
8A @ 12V
3A @ -12V
40A @ 5V
50A @ 3.3V
8A @ 12V
3A @ -12V
Minimum Load 0.75A @ +12V 0.75A @ +12V 0.5A @ +5V 0.5A @ +5V 1.0A @ +5V 1.0A @ +5V
Rated Power Typical 250W Typical 250W Typical 250W continuous Typical 250W continuous Typical 400 W continuous Typical 400 W continuous
Ripple 60 mV @ +5 V and 3.3 V outputs
120 mV @ +12 V and -12 V outputs
60 mV @ +5 V and 3.3 V outputs
120 mV @ +12 V and -12 V outputs
50 mV @ +5 V and 3.3 V outputs
120 mV @ +12 V and -12 V outputs
50 mV @ +5 V and 3.3 V outputs
120 mV @ +12 V and -12 V outputs
50 mV @ +5 V and 3.3 V outputs
120 mV @ +12 V and -12 V outputs
50 mV @ +5 V and 3.3 V outputs, 120 mV @ +12V and -12V
outputs
50 mV @ +5 V and 3.3 V outputs, 120 mV @ +12V and -12V
outputs
Hold-up Time 20 ms 4 ms 5 ms after power fail signal 5 ms after power fail signal 30 ms 10 ms after power fail signal 10 ms after power fail signal
Efficiency Typical 82.6% Typical 82.2% Typical 78-79% Typical 85-89% Typical 79-83% Typical 79-83%
Output
voltage sense
Available at 5V, 3.3V, and +12V outputs Available at 5V, 3.3V, and +12V outputs Available at 5V, 3.3V, and +12V outputs and current sharing Available at 5V, 3.3V, and +12V outputs and current sharing Available at 5V, 3.3V, and +12V outputs and current sharing Available at 5 V , 3.3 V and +12 V outputs Available at 5 V , 3.3 V and +12 V outputs
N+1
Redundancy
Integrated ORing FETs / diodes for true redundancy Integrated ORing FETs / diodes for true redundancy Equipped with internal OR-ing diodes at all outputs for N+1 redundancy operation Equipped with internal OR-ing diodes at all outputs for N+1 redundancy operation Equipped with internal OR-ing diodes at all outputs for N+1
redundancy operation
Installed with internal OR-ing diodes at all outputs for N+1
redundancy operation
Installed with internal OR-ing diodes at all outputs for N+1
redundancy operation
Remote
ON/OFF
Available at [INH#] & [EN#] Available at [INH#] & [EN#] Available at [INH#] & [EN#] Available at [INH#] & [EN#] Available at [INH#] & [EN#] Available at [INH#] & [EN#] Available at [INH#] & [EN#]
Power
Failure Signal
Available at [FAL#] pin Available at [FAL#] pin Available at [FAL#] pin Available at [FAL#] pin Available at [FAL#] pin Available at [FAL#] pin Available at [FAL#] pin
Voltage
Degrade
Signal
Available at [DEG#] pin Available at [DEG#] pin Available at [DEG#] pin Available at [DEG#] pin Available at [DEG#] pin Available at [DEG#] pin Available at [DEG#] pin
Status LED [INPUT OK] [FAULT] [INPUT OK] [FAULT] [POWER] means valid input voltage[FAULT] means a critical fault [POWER] means valid input voltage[FAULT] means a critical fault [POWER] valid input voltage [FAULT] critical fault < Green LED > [POWER] means valid input voltage
< Amber LED > [FAULT] means a critical fault
< Green LED > [POWER] means valid input voltage
< Amber LED > [FAULT] means a critical fault
Earth Leakage <0.5 mA @ 230 VAC <0.5 mA @ 48 VDC <0.5 mA @ 24 VDC <0.5 mA @ 230 VAC <0.5 mA @ 48 VDC <0.5 mA @ 24 VDC < 0.9mA @ 230 V AC > N/A
Operating
Temperature
-25°C to +50°C
(-25°C to +105°C at case level)
-25°C to +50°C
(-25°C to +105°C at case level)
0˚C to +70˚C
(0˚C to +50˚C at full load with specified air flow.
Derates linearly to 50% at +70˚C.)
0˚C to +70˚C
(0˚C to +50˚C at full load with specified air flow.
Derates linearly to 50% at +70˚C.)
-40°C to +85°C with free convention to supply up to 120W or
with at least 400 LFM air flow to supply up to 300W
0°C to +70°C
(0 ̊C to +40 ̊C at full load with specified air flow.
De-rates linearly to 50% at +70°C.)
0°C to +70°C
(0 ̊C to +40 ̊C at full load with specified air flow.
De-rates linearly to 50% at +70°C.)
Storage
Temperature
-40˚C to +85˚C -40˚C to +85˚C -40˚C to +85˚C -40˚C to +85˚C -40˚C to +90˚C -20 ̊C to +85 ̊C -20 ̊C to +85 ̊C
Humidity 5% to 95% non-condensing 5% to 95% non-condensing 5% to 95% non-condensing 5% to 95% non-condensing 5% to 95% non-condensing 20% to 90% non-condensing 20% to 90% non-condensing
Shock 20 G Acceleration amplitude, 11 ms duration, converter operating 20 G Acceleration amplitude, 11 ms duration, converter operating 15 G peak-to-peak, 11 ms duration, non-operation 15 G peak-to-peak, 11 ms duration, non-operation 15 G peak-to-peak, 11 ms duration, non-operation 15 G peak-to-peak, 11 ms duration, non-operation 15 G peak-to-peak, 11 ms duration, non-operation
Vibration Operation: 4.9 Grms, 20-500Hz, each axis Operation: 2.2 Grms, 20-500 Hz, each axis Operation: 1.88 Grms, 5-500 Hz, each axis Operation: 1.88 Grms, 5-500 Hz, each axis Operation: 1.88 Grms, 5-500 Hz, each axis Operation: 1.88 Grms, 5-500 Hz, each axis Operation: 1.88 Grms, 5-500 Hz, each axis
Cooling Requirement Min. 20 CFM is required for typical full power rating Min. 20 CFM is required for typical full power rating Minimum 20 CFM airflow is required for typical full rating
power
Minimum 20 CFM airflow is required for typical full rating
power
Certifications IEC/EN 60950-1, UL/CSA 60950-1 IEC/EN 60950-1, UL/CSA 60950-1 IEC950, EN 55022, FCC Class A, IEC60950 Class I IEC950, EN 55022, FCC Class A, IEC60950 Class I EN 61000-4-3, EN 61000-4-5, EN 61000-4-6, EN 55022, FCC
Class A, IEC 60950 Class I
IEC950, EN 55022, FCC Class A, IEC60950 Class I IEC950, EN 55022, FCC Class A, IEC60950 Class I
MTBF 279.000 h 288.000 h 240.500 h 240.500 h
Ordering Information cPS-P325/AC cPS-P325/48 cPS-H325/24 cPS-H325/110 cPS-H325/WDC cPS-H640/AC cPS-H640/48